HLERT-XXX
HydroLERT Level Alarm Systems - COMING SOON
Simple, visible alarm protection for tanks, sumps, and process applications.

Overview
HydroLERT® is a compact and versatile alarm controller designed to detect one or two alarm conditions using digital switches or a conductivity probe. It provides clear local audible and visual warning for level, pressure, flow, temperature, and other limit-alarm applications.
WHY CHOOSE HydroLERT
- Two configurable inputs and selectable operating modes support flexible single- or dual-level monitoring.
- Early warning helps reduce the risk of tank or sump overflow.
Low-level warning can help protect pumps and systems from dry-run conditions. - Audible buzzer and high-visibility strobe provide clear local alarm indication.
- Mute and hold-to-test functions make local operation and routine testing simple.
- Flexible sensor compatibility supports float, pressure, temperature, and flow switches, plus conductivity sensing.
BUILT FOR PRACTICAL INSTALLATIONS
- Compact IP65-rated ABS enclosure for wall or pole mounting.
- Adjustable alarm delay from 2 seconds to 18 minutes.
- Voltage-free BMS/common-fault output and 12 Vdc remote buzzer output.
- Battery-backup model keeps alarm capability available during mains power loss.
- Suitable for new installations and retrofit applications across water, wastewater, irrigation, and process systems.
COMMON APPLICATIONS
- Water storage tanks
- Pump stations and sumps
- Wastewater and stormwater systems
- Irrigation and rural water systems
- Chemical and process tanks
- Pressure, flow, and temperature limits
- Commercial and industrial facilities
PAIR WITH
- Float switches for high-, low- or critical-level alarm points
- Conductivity probe for liquid-level detection
- Pressure switches
- Temperature switches
- Flow switches
- Remote buzzer for additional alarm indication
Product Details
HARDWARE FEATURES
- Enclosure:
- IP65-rated ABS enclosure with UV stabiliser and in-built mounting brackets
- Protection:
- 12 V DC low-voltage control and input circuitry
- Control & Interface:
- Visual (strobe) and audible (buzzer) alarm indicators
- Indicator light for power on, battery mode, standard and critical alarms
- Alarm mute and test pushbutton
- 12 V DC 1.3 Ah battery backup (BBU model only)
- 4 selectable DIP-switch operating modes
- Adjustable alarm delay
- Inputs:
- 240 V AC supply via 10 A 3-pin plug and 1.75 m lead
- Digital 12 V DC switch input and conductivity probe input
- Outputs:
- BMS volt-free output for common fault (NO & NC)
- Remote buzzer 12 V DC output
TECHNICAL SUMMARY
- Alarm operation:
- One or two set point alarm
- Sensor compatibility:
- Digital inputs or conductivity probe
- Local indication:
- Audible and visual alarm indication
- User controls:
- Alarm mute / test
- Battery backup:
- Available in HLERT-BBU model
- Mounting:
- Wall or pole-mounted controller
- Power Supply:
- 1ph, 240 V AC - 10 A 3-pin 1.75 m lead
FUNCTIONS
- High level warning:
- Provides early warning to help prevent tank or sump overflow
- Low level warning:
- Helps protect pumps and systems from dry-run conditions
- Alarm acknowledgement:
- Mute and test functions provide simple local operation
- Power failure protection:
- Battery backup model supports continued alarm monitoring
- Option to activate alarm on power fail
SKU Details
| Code | Description | Enclosure Size |
| HLERT-S | Level Alarm - Standard IP65 240 V AC | 243mm H x 122mm W x 74mm D |
| HLERT-BBU | Level Alarm - Battery Backup IP65 240 V AC | 243mm H x 122mm W x 74mm D |
Product Support Material
Filters
0resources
Loading…
Related Products

FPC-12652
12VDC Strobe & Buzzer Remote Alarm Indicator
12VDC remote alarm indicator with visual strobe, buzzer, mute control, and IP54 protection.

FPC-12653
240VAC Strobe & Buzzer Remote Alarm Indicator
Remote alarm indicator with visual strobe, audible alarm, and IP54 enclosure.

FPC-12664
Deluxe High and Low Set-Point Alarm
Ultimate dual set-point alarm with high & low indication, mute control, and IP54 enclosure.

FPC-12670
Deluxe Set-Point Alarm
The ultimate alarm panel, flexible expansion, communications, robust IP54 metal enclosure.

FPC-12656
Flush Mount Level Alarm
Compact flush mount level alarm with audible warning, status indicators and mute control.

FPC-12655
Remote Indicator Strobe
12/24VDC remote visual strobe indicator for alarm and control panels with IP54 protection.

FPC-12650
Standard Set-Point Alarm
Standard set-point alarm with keypad, status indication, and robust IP54 enclosure.

FPC-12651
Standard Set-Point Alarm Plus
Advanced alarm with strobe, flexible connections, keypad control, and status indication.

FPC-12596-XXX
6kVA Battery Back-up
6kVA inverter back-up unit with IP44 enclosure, intelligent battery monitoring, and 225Ah or 450Ah capacity.

FPC-12597-XXX
8kVA Battery Back-up
8kVA inverter back-up unit in an IP44-rated free-standing enclosure with intelligent battery monitoring.

FPC-12718
Advanced Dual Tank Level Indicator
Monitors two tanks via dual 4–20mA inputs; IP44 mild steel enclosure with HMI, data logging, and Modbus RTU.

FPC-1272X
Deluxe Rain/Mains Valve & Pump Controller
IP56-rated controller that manages rain/mains switchover and pressure pump operation via tank level monitoring.