DET-SMK/DC/1 & DET-SMK/DC/10 Smoke Alarm Troubleshooting Guide

DET-SMK/DC/1 & DET-SMK/DC/10
DET-SMK/DC/1 & DET-SMK/DC/10 SMOKE ALARM TROUBLESHOOTING GUIDE
Troubleshooting guide and other resources for the DET-SMK/DC/1 & DET-SMK/DC/10 standalone smoke alarms from MATelec Australia
TESTING THE ALARMS
Testing Your DET-SMK/DC/1 & DET-SMK/DC/10 Smoke Alarms
We recommend testing your DET-SMK/DC/1 & DET-SMK/DC/10 Smoke Alarms monthly to confirm they are functioning correctly and ready to provide reliable protection.
- 1
Locate the Test Button
Locate the large Test/Hush button on the front of the smoke alarm.
- 2
Press and Hold Test Button
Press and hold the Test button.
The alarm will sound and the red LED will flash rapidly while the button is pressed. This confirms the smoke alarm is operating correctly.
- 3
Release Test Button
Release the Test button and allow the smoke alarm to return to normal operation.
- 4
Check Flashing LED
During normal standby operation:
- DET-SMK-DC1: Red LED flashes every 32 seconds.
- DET-SMK-DC10: Red LED flashes every 40 seconds.
Regular testing is one of the simplest ways to help ensure your MATelec smoke alarms continue to provide reliable protection.
LED SIGNALS & AUDIBLE ALERTS
LED Signals & Audible Alerts Reference Table
Function | DET-SMK/DC/1 Indication | DET-SMK/DC/10 Indication | Description |
|---|---|---|---|
Standby Status (Normal operation) | Red LED flashes every 32 seconds | Red LED flashes every 40 seconds | Normal operation |
Low Battery Warning | The unit chirps & Red LED flashes once every 32 seconds. | The unit chirps & Red LED flashes once every 40 seconds. | Low battery voltage - replace with a new battery |
Fault Warning | The unit beeps twice and flashes twice every 32 seconds | The unit beeps once with no LED flash | The unit may be faulty - refer to “Trouble Shooting” section. |
End-of-life Warning | The unit chirps & Red LED flashes twice every 32 seconds | The unit chirps twice & Red LED flashes twice every 40 seconds | The unit will send end-of-life warning after working 10 years. Replace with a new smoke alarm. |
Test Function | Red LED flashes once every second with alarm sounding until the TEST button is released. | Red LED flashes once every second with alarm sounding until the TEST button is released. |
|
Hush Mode | The Red LED flashes every 8 seconds. | The Red LED flashes every 8 seconds. |
|
Alarm Triggered | The Red LED flashes every second with alarm sounding | The Red LED flashes every second with alarm sounding | Smoke (or false trigger) detected and alarm sounds. |
Do Not Disturb Function | Red LED flashes once every 32 seconds | Red LED flashes once every 40 seconds | When the unit indicates a low battery, pushing the HUSH button will silence the alarm for 10 hours and red LED will flash once every 48 seconds. |
Do Not Disturb Function | Red LED flashes twice every 32 seconds | Red LED flashes twice every 40 seconds | When the unit indicates an internal fault, pushing the HUSH button will silence the alarm for 10 hours and red LED will flash twice every 48 seconds. |
For more guidance, watch the videos:
Understanding the LED Signals and Audible Alarms
Understanding the LED signals and audible alarms on MATelec DET-SMK/AC/1 and /10 Smoke Alarms
Using HUSH Mode & Locating Triggered Alarms
Using HUSH mode & locating triggered alarms on MATelec DET-SMK/AC/1 & /10 and RF/AC/1 & /10 Smoke Alarms
USING HUSH MODE
Using Hush Mode
HUSH mode allows you to temporarily silence your MATelec DET-SMK-DC1 or DET-SMK-DC10 smoke alarm after you have confirmed there is no fire or smoke hazard.
IMPORTANT: Always check for signs of smoke or fire before using HUSH mode. Never assume an alarm is false without checking first.
- 1
Check the Area
If the smoke alarm sounds, first check the surrounding area for signs of smoke or fire.
Only use HUSH mode once you have confirmed it is safe to do so.
- 2
Activate Hush Mode
Press the Test/Hush button to temporarily silence the alarm.
The smoke alarm will stop sounding but will continue to monitor for smoke.
- 3
Check the LED
While HUSH mode is active, the red LED will flash every 8 seconds.
- 4
Allow The Alarm to Return to Normal Operation
The HUSH period differs between the two models:
- DET-SMK-DC1: Approximately 8 minutes.
- DET-SMK-DC10: Approximately 10 minutes.
Once the HUSH period has ended, the smoke alarm will automatically return to normal operation.
If smoke or another triggering source is still present, the alarm will sound again.
Remember: HUSH mode should only be used once you have confirmed there is no fire or smoke hazard.
DET-SMK/DC/1 BATTERY INFORMATION
DET-SMK/DC/1 Smoke Alarm Battery Information
The DET-SMK/DC/1 features a replaceable 1-year 9V battery and is designed with a 10-year smoke alarm service life.
When the battery is running low, the alarm will chirp and the red LED will flash every 32 seconds. Replace the battery as soon as possible to maintain reliable protection.
- 1
Remove the Alarm
Twist the alarm head anticlockwise until it stops, then remove it from the mounting base.
- 2
Replace the Battery
Remove the depleted battery and install a new 9V alkaline or carbon battery, ensuring it is fitted in the correct orientation.
- 3
Refit the Alarm
Align the alarm with the mounting base and twist it clockwise until it locks securely into place.
- 4
Check Normal Operation
Confirm the red LED flashes every 32 seconds to indicate normal operation.
- 5
Test the Alarm
Press and hold the Test button until the alarm sounds to confirm the smoke alarm is operating correctly.
END-OF-LIFE WARNING
The DET-SMK/DC/1 has a 10-year service life.
At the end of its service life, the alarm will chirp and the red LED will flash twice every 32 seconds.
When this occurs, replace the complete smoke alarm.
DET-SMK/DC/10 BATTERY INFORMATION
DET-SMK/DC/10 Smoke Alarm Battery Information
The DET-SMK/DC/10 features a sealed, non-replaceable 10-year lithium battery designed to last for the service life of the smoke alarm.
Unlike the DET-SMK/DC/1, the battery cannot be replaced.
END-OF-LIFE WARNING
The DET-SMK/DC/10 has a 10-year service life.
At the end of its service life, the alarm will chirp twice, and the red LED will flash twice every 40 seconds.
As the battery is sealed and non-replaceable, the complete smoke alarm must be replaced.